BTF series

BTF Series Filter Cartridges are constructed of hydrophobic polytetrafluoroethylene (PTFE) membrane, PTFE support netting, and ultra-pure perfluoroalkyl (PFA) hardware. This provides the ultimate in chemical compatibility, durability, and extraordinarily

Learn More

 

BTF Series Filter Cartridges are constructed of hydrophobic polytetrafluoroethylene (PTFE) membrane, PTFE support netting, and ultra-pure perfluoroalkyl (PFA) hardware.  This provides the ultimate in chemical compatibility, durability, and extraordinarily low extractables.  And furthermore provides high retention efficiency and long service life with aggressive chemicals. 

 

Features

  • Ultimate chemical compatibility.
  • 100% integrity tested.
  • High flow rate with low pressure drop.

 

Applications

  • Pharmaceutical products 
  • Chemically aggressive fluids
  • Solvents, strong acids & bases 
  • Fine chemicals
  • Microelectronic process fluids

 

Quality 

  • Individually tested for integrity.
  • Filter cartridges are manufactured in a clean room environ- ment   using   Good   Manufacturing   Practices   under   an ISO9001:2015 registered Quality Management System.
  • Cartridges are individually serialized and have full materials traceability.

 

Specifications

Dimensions
OD 69mm (2.72”) OD & 83mm (3.3”) OD
Lengths 10”, 20”, 30”, 40”
Filtration Area
HP 1.12m2/69-10”    1.63m2/83-10”
EP 0.9m2/69-10”      1.51m2/83-10”
Material of Constructions
Media Hydrophobic PTFE 
Support Layers PFA/PTFE
Cage/Core/End Caps  PFA
Seal Material Options E-FKM
Operating Limits
Max. Temperature  160° C (320° F)
Max. dP (forward) 5 bar (73 psi) @ 20°C (68°F)
  2 bar (30 psi) @ 120°C (248°F)
SIP 135°C (275°F) @ 30 minutes recommended

 

Wetting Precautions

  • PTFE membrane is naturally hydrophobic.  If used with high surface tension fluids, such as aqueous solutions, it's neces-sary to pre-wet the filter cartridge.  Alternatively, specify a pre-wetted cartridge.
  • Pre-wetted cartridges are shipped in a solution of preserved ultrapure water.  At the time of installation, drain the liquid and rinse the filter with 20L (per 10” unit) ultrapure water or service fluid before use.
  • If pre-wetting is required, soak the cartridge in an aqueous solution of 60% isopropanol (IPA) for 10 minutes. Remove cartridge from the IPA and soak in ultrapure water for 10 minutes.  Or, rinse for 10 minutes at 7.5 LPM per 10” length. The cartridge is now ready for service.

 

Flow Rate vs Pressure Drop

 

Flow Rate vs Pressure Drop

 

catelog